| Model |
|
HV-25 |
|
HV-50 |
|
HV-85 |
|
HV-110 |
| Outside dimensions |
|
480W ¡¿ 460D ¡¿ 950 H |
|
540W ¡¿ 530D ¡¿ 1000H |
|
660W ¡¿ 650D ¡¿ 1000H |
|
660W ¡¿ 650D ¡¿ 1180H |
| (Height with lid open) |
( 1220 ) |
( 1370 ) |
( 1440 ) |
( 1610 ) |
| Chamber size |
|
250¥õ ¡¿ 550 Dmm |
|
364¥õ ¡¿ 710 Dmm |
|
420¥õ ¡¿ 615 Dmm |
|
420¥õ ¡¿ 795 Dmm |
| (Capacity) |
|
( 25§¤ ) |
|
( 50§¤ ) |
|
( 85§¤ ) |
|
( 110 §¤ ) |
| Power sourec |
|
AC 110V/ 120V/ 220V/ 230V/ 240V, 50 / 60 Hz |
|
AC 220V/ 230V/ 240V, 50 / 60 Hz |
| |
|
(Specify the voltage when ordering) |
|
(Specify the voltage when ordering) |
| Power consumption |
|
1.5 kW |
|
2.0 kW |
|
3.0 kW |
|
4.0 kW |
| Net weitht (approx.) |
|
41 Kg |
|
57 Kg |
|
71 Kg |
|
81 Kg |
| Sterilization temperature |
|
150 to 126 ¡É |
|
150 to 135 ¡É |
| Maximum allowable |
|
0.41 Mpa |
|
0.26 Mpa |
| pressure (Gauge pressure) |
|
|
|
|
| Temperature display range |
|
5 to 128 ¡É |
|
50 to 137 ¡É |
| Warming temperature |
|
40 to 60 ¡É |
| Agar dissolution |
|
|
| temperature range |
|
60 to 100 ¡É |
| Chamber material |
|
SUS304 (Stainiess steel) |
| Sterilization timer |
|
1 to 250 minutes |
| Auto start timer |
|
1 minutes to 7 days |
| Pressure gauge |
|
0 to 0.4 Mpa |
| Selective Mode |
|
Sterilization of agar |
|
Preparation ¡æ Heating ¡æ Sterillaztion ¡æ Exhaust(Slow/adjustable) ¡æ Warming |
| |
|
(with Warming) |
|
¡æ Completion |
| |
|
Sterilization of liquids : |
|
Preparation ¡æ Heating ¡æ Sterillaztion ¡æ Exhaust(Slow/adjustable) ¡æCompletion |
| |
|
Sterilization of solids / |
|
Preparation ¡æ Heating ¡æ Sterillaztion ¡æ Exhaust(Fast) ¡æCompletion |
| |
|
medical instruments |
|
|
| |
|
Agar dissolution |
|
Preparation ¡æ Heating ¡æ Warming ¡æCompletion |
| Safety devices/ |
|
¢¹Double sensing inter lock mechanism ¢¹Over-pressure power cut-off |
| Warning alarms |
|
¢¹Sterilizing time counting timer Electric leakage breaker and over current detector |
| |
|
¢¹Temperature sensor wire breakage detecte ¢¹Securely closed lid check function |
| |
|
¢¹Exhaust bottle ready-to-use check system ¢¹Lack-of-water prevention device Pressure safety valve |
| |
|
¢¹Heater malfunction checker ¢¹Over-temperature power cut-off |
| |
|
( Note: The ¢Â marked functions show ERORR indicatio on the display when it works) |
| Standard accessories |
|
Stainless steel wire baskets, Heater cover, Drain hose, Exhaust bottle, Caster stoppers. |
| Optional accessories |
|
Stainless steel wire baskets, Stainless steel buckets, Hook for basket / bucket (for HV-110 only). |
|
|
|