| Model |
|
PC-304R8 |
|
PC-422R8 |
|
PC-304R8D |
|
PC-422R8D |
|
|
|
|
|
|
|
|
|
| Dimensions |
|
709 W ¡¿ 950 D ¡¿ 1674 H mm |
|
900 W ¡¿ 1100 D ¡¿ 1780 H mm |
| Test Chamber Size |
|
300 ¥õ ¡¿ 373 D mm(26L) |
|
420 ¥õ ¡¿ 485 D mm(67L) |
|
300 ¥õ ¡¿ 373 D mm(26L) |
|
420 ¥õ ¡¿ 485 D mm(67L) |
| |
|
|
(per Chamber) |
(per Chamber) |
| Effective Camber Size |
|
220 ¥õ ¡¿ 350 D mm(12L) |
|
340 ¥õ ¡¿ 475 D mm(40L) |
|
220 ¥õ ¡¿ 350 D mm(26L) |
|
340 ¥õ ¡¿ 475 D mm(40L) |
| |
|
|
(per Chamber) |
(per Chamber) |
| Net Weight |
|
Approx. 260kg |
|
Approx. 280kg |
|
Approx. 470kg |
|
Approx. 480kg |
| Power(AC 1ph 220 / 230 / 240V 50/60Hz) |
|
2.5kW |
|
3.2kW |
|
2.5kW(per Chamber) |
|
3.2kW(per Chamber) |
| Heater |
|
Steam Generator 1.7kW |
|
Steam Generator 1.7kW |
|
Steam Generator 1.7kW |
|
Steam Generator 1.7kW |
| Capacity |
|
Test Chamber 0.6kW |
|
Test Chamber 1.3kW |
|
Test Chamber 0.6kW |
|
Test Chamber 0.6kW |
| |
|
|
|
|
|
(per Chamber) |
|
(per Chamber) |
| Operation Mode |
|
Program Mode and Fixed Mode |
| Program |
|
Programmable up to 100 patterns, 800 steps |
| Testing mode |
|
HUM (unsaturated) and STD (saturated) |
| Tem. Control |
|
PID / SSR |
| Testing mode |
|
HUM (unsaturated) and STD (saturated) |
| Testing |
|
105.0 ~ 151.4¡É/100%RH |
|
105.0 ~ 133.3¡É/100%RH |
|
105.0 ~ 151.4¡É/100%RH |
|
105.0 ~ 133.3¡É/100%RH |
| Temperature |
|
110.0 ~ 157.5¡É/ 85%RH |
|
110.0 ~ 140.0¡É/ 85%RH |
|
110.0 ~ 157.5¡É/ 85%RH |
|
110.0 ~ 140.0¡É/ 85%RH |
| Range |
|
118.0 ~ 162.5¡É/ 65%RH |
|
118.0 ~ 150.0¡É/ 65%RH |
|
118.0 ~ 162.5¡É/ 65%RH |
|
118.0 ~ 150.0 ¡É/ 65%RH |
| Tem. Control Accuracy |
|
¡¾ 0.5¡É |
| Distributing |
|
¡¾ 0.5 ¡É( at 100%RH) |
| Accuracy |
|
¡¾ 1.05 ¡É( at 85%RH) |
| Hum. Range |
|
65 ~ 100%RH |
| Distributing |
|
¡¾3%RH( at 85%RH) |
| Press. Ranget |
|
0.019 ~ 0.393 MPa |
|
0.019 ~ 0.208 MPa |
|
0.019 ~ 0.393 MPa |
|
0.019 ~ 0.208 MPa |
| Test Time |
|
Max. 500hrs. Continuously |
| Time Range |
|
1 min. ~ 999hrs. 59 min |
| Inst. Blackout back up |
|
Approx. 4sec. |
| Time to Reach Rated Temp |
|
Approx. 70 min.(Room Temp. ¡æ 120¡É, 85%RH) |
| Exhaust Mode |
|
Mode Switch 1, 2 and 3 (Ref. Page 4) |
| Bias Terminal |
|
20 per Chamber (125V up to total 30W)(Ref. Page 3) |
| Chamber |
|
Stainless steel SUS316L |
| Water Supply |
|
Automatic water supply from built-in Water Tank (Ref. Page 4) |
| Door System |
|
Motor-driven clamping system, with Siding Tray |
| |
|
Prssure safety valve, Proof to overpressure, overheating and no-water heating, Feed-water failure sensor, |
| Water Supply |
|
Electric leakage breaker (with OC), Breaker for heater, Temperature fuse, Safety door system, |
| |
|
Rated value Locking device, Sequence control self-checking device, Hot water dischange system, |
| |
|
Negative pressure prevention device |
| Standard Accessories |
|
Drain hose : 2pc, Feed-water hose : 1pcs, Aux.feed-water tank : 1pc, Lid gasket : 2pcs, |
| |
|
Power SW Key : 2pcs(R8D : 4pcs), Power cord : 4pcs(R8D : 2pcs), Operation manual : 1pc |
|
|
|